Allen-Bradley 1769-IA16 Digital Input Module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1769-IA16 Digital Input Module
  • Inputs: 16; Voltage category: 120 V AC
  • Operating voltage: 79–132 V AC

Specification

Allen-Bradley 1769-IA16 — Digital Input Module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1769-IA16
Inputs16
Voltage category120 V AC
Operating voltage79–132 V AC
Manufacturer approximate product weight0.28 kg — packaging inclusion not specified
1769-TD006H-EN-P (November 2023), p. 7

Ordering & Compatibility

Match the nominal 120 V AC category and specified operating-voltage window.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1769-IA16 Procurement Questions

What is the operating voltage range of the 1769-IA16?

The operating voltage range is 79…132V AC, 47…63 Hz, within the 100/120V AC voltage category.

How many inputs does the 1769-IA16 provide and how are they grouped?

It provides 16 inputs, arranged as 16 points/group with internally connected commons.

What are the on-state and off-state thresholds?

On-state voltage minimum is 79V AC; on-state current minimum is 5 mA @ 74V AC and maximum is 12 mA @ 120V AC. Off-state voltage maximum is 20V AC and off-state current maximum is 2.5 mA.

What is the maximum inrush current and can it be limited?

Maximum inrush current is 250 mA. Per footnote (1) of Table 4, a current limiting resistor can be used to limit inrush current, but the operating characteristics of the AC input circuit will be affected: if a 6.8 kΩ (2.5 W minimum) resistor is placed in series with the input, the inrush current is reduced to 35 mA, and in this configuration the minimum on-state voltage increases to 92V AC. Before adding the resistor in a hazardous environment, consider the operating temperature of the resistor and the temperature limits of the environment; the resistor's operating temperature must remain below the temperature limit of the environment.

What isolation is specified for the 1769-IA16?

Isolation voltage is verified by one of the following dielectric tests: 1517V AC for 1 s or 2145V DC for 1 s, input point to bus, with 132V AC working voltage (IEC Class 2 reinforced insulation).

Which power supplies are listed and how far from the supply can the module be placed?

The listed power supplies are 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4, and the power supply distance rating is 8 modules.

Inputs
16 (16 points/group, internally connected commons)
Voltage category
100/120V AC
Operating voltage range
79…132V AC, 47…63 Hz
Input delay, on
20 ms
Input delay, off
20 ms
Current draw @ 5.1V
115 mA
Heat dissipation, max
3.30 W
Off-state voltage, max
20V AC
Off-state current, max
2.5 mA
On-state voltage, min
79V AC
On-state current, min
5 mA @ 74V AC
On-state current, max
12 mA @ 120V AC
Inrush current, max
250 mA (footnote (1) of Table 4: A current limiting resistor can be used to limit inrush current; however, the operating characteristics of the AC input circuit will be affected. If a 6.8 kΩ (2.5 W minimum) resistor is placed in series with the input, the inrush current is reduced to 35 mA. In this configuration, the minimum on-state voltage increases to 92V AC. Before adding the resistor in a hazardous environment, be sure to consider the operating temperature of the resistor and the temperature limits of the environment. The operating temperature of the resistor must remain below the temperature limit of the environment.)
Input impedance, max
12 kΩ @ 50 Hz 10 kΩ @ 60 Hz
Isolation voltage
Verified by one of the following dielectric tests: 1517V AC for 1 s or 2145V DC for 1 s, input point to bus 132V AC working voltage (IEC Class 2 reinforced insulation)
Weight, approx (product weight as published)
280 g (0.61 lb)
Dimensions (HxWxD), approx
118 x 35 x 87 mm (4.65 x 1.38 x 3.43 in.) Height with mounting tabs 138 mm (5.43 in.)
Slot width
1
Module location
DIN rail or panel mount
Power supply
1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4
Power supply distance rating
8 modules
Terminal screw torque
0.68 N·m (6 lb·in)
Retaining screw torque
0.46 N·m (4.1 lb·in)
Wire size
(22…14 AWG) solid (22…16 AWG) stranded
Wire type
Cu-90 °C (194 °F)
IEC input compatibility
Type 1+
Replacement terminal block
1769-RTBN18 (1 per kit)
Replacement door label
1769-RL1 (2 per kit)
Replacement door
1769-RD (2 per kit)
Vendor ID code
1
Product type code
7
Product code
82
Enclosure type rating
None (open-style)

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp