Allen-Bradley 1769-OW8I Digital Output Module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1769-OW8I Digital Output Module
  • Outputs: 8 normally open, individually isolated; Output type: AC/DC relay contact
  • Operating voltage: 5–265 V AC / 5–125 V DC

Specification

Allen-Bradley 1769-OW8I — Digital Output Module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1769-OW8I
Outputs8 normally open, individually isolated
Output typeAC/DC relay contact
Operating voltage5–265 V AC / 5–125 V DC
Manufacturer approximate product weight0.29 kg — packaging inclusion not specified
1769-TD006H-EN-P (November 2023), p. 27

Ordering & Compatibility

Specify the individually isolated I variant and verify relay contact load ratings separately.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1769-OW8I Procurement Questions

What output configuration does the 1769-OW8I provide?

It provides 8 normally open, individually isolated outputs, arranged as 4 points/group.

What load voltage range can the relay outputs switch?

The operating voltage range is 5…265V AC and 5…125V DC.

What are the current limits per point and per module?

Current per point, max is 2.5 A, and current per module, max is 16 A.

What relay contact ratings apply at 240V AC and at 120V AC?

At 240V AC: continuous amps per point, max 2.5 A; make 7.5 A; break 0.75 A; voltamperes, make 1800VA; voltamperes, break 180VA; NEMA ICS 2-125: C300. At 120V AC: continuous amps per point, max 2.5 A; make 15 A; break 1.5 A; voltamperes, make 1800VA; voltamperes, break 180VA.

What are the DC relay contact ratings and the condition for DC applications?

At 125V DC: continuous amps per point, max 1.0 A; break 0.22 A; voltamperes, break 28VA; NEMA ICS 2-125: R150. At 24V DC: continuous amps per point, max 2.0 A; break 1.2 A; voltamperes, break 28VA; NEMA ICS 2-125: —. Per footnote (2) of Table 82: for DC voltage applications, the make/break ampere rating for relay contacts can be determined by dividing 28VA by the applied DC voltage; for example, 28VA/48V DC = 0.58 A; for DC voltage applications less than 48V, the make/break ratings for relay contacts cannot exceed 2 A.

Which power supplies are listed for this module, and what is its power supply distance rating?

The listed power supplies are 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4, and the power supply distance rating is 8 modules.

Outputs
8 normally open, individually isolated (4 points/group)
Operating voltage range
5…265V AC 5…125V DC
Delay, on
10 ms
Delay, off
10 ms
Current draw @ 5.1V
125 mA
Current draw @ 24V
100 mA
Heat dissipation, max
2.83 W
Off-state leakage, max
0 mA
On-state current, min
10 mA @ 5V DC
Current per point, max
2.5 A
Current per module, max
16 A
Isolation voltage
Verified by one of the following dielectric tests: 1836V AC for 1 s or 2596V DC for 1 s, output point to bus 265V AC working voltage (IEC Class 2 reinforced insulation) Verified by one of the following dielectric tests: 1836V AC for 1 s or 2596V DC for 1 s, group to group 265V AC working voltage (basic insulation) 150V AC working voltage (IEC Class 2 reinforced insulation)
Weight, approx (product weight as published)
290 g (0.64 lb)
Dimensions (HxWxD), approx
118 x 35 x 87 mm (4.65 x 1.38 x 3.43 in.) Height with mounting tabs 138 mm (5.43 in.)
Slot width
1
Module location
DIN rail or panel mount
Power supply
1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4
Power supply distance rating
8 modules
Terminal screw torque
0.68 N·m (6 lb·in)
Retaining screw torque
0.46 N·m (4.1 lb·in)
Wire size
(22…14 AWG) solid (22…16 AWG) stranded
Wire type
Cu-90 °C (194 °F)
Replacement terminal block
1769-RTBN18 (1 per kit)
Replacement door label
1769-RL1 (2 per kit)
Replacement door
1769-RD (2 per kit)
Vendor ID code
1
Product type code
7
Product code
87
Enclosure type rating
None (open style)
Relay contact rating @ 240V AC
Continuous amps per point, max: 2.5 A; Make: 7.5 A; Break: 0.75 A; Voltamperes, make: 1800VA; Voltamperes, break: 180VA; NEMA ICS 2-125: C300
Relay contact rating @ 120V AC
Continuous amps per point, max: 2.5 A; Make: 15 A; Break: 1.5 A; Voltamperes, make: 1800VA; Voltamperes, break: 180VA
Relay contact rating @ 125V DC
Continuous amps per point, max: 1.0 A; Break: 0.22 A; Voltamperes, break: 28VA; NEMA ICS 2-125: R150 (footnote (2) of Table 82: For DC voltage applications, the make/break ampere rating for relay contacts can be determined by dividing 28VA by the applied DC voltage. For example, 28VA/48V DC = 0.58 A. For DC voltage applications less than 48V, the make/break ratings for relay contacts cannot exceed 2 A.)
Relay contact rating @ 24V DC
Continuous amps per point, max: 2.0 A; Break: 1.2 A; Voltamperes, break: 28VA; NEMA ICS 2-125: —

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp