Allen-Bradley 1756-L61S GuardLogix primary controller

Series#: AllenBradley

Product Details

  • Allen-Bradley 1756-L61S GuardLogix primary controller
  • Role: GuardLogix primary controller
  • Safety partner: 1756-LSP

Specification

Allen-Bradley 1756-L61S — GuardLogix primary controller.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1756-L61S
RoleGuardLogix primary controller
Safety partner1756-LSP

Ordering & Compatibility

Confirm the required primary controller and its separate safety partner.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1756-L61S Procurement Questions

How much user memory and safety memory does the 1756-L61S provide?

The 1756-L61S provides 2 MB of user memory and 1 MB of safety memory.

What is the maximum I/O capacity of the 1756-L61S?

The maximum digital I/O is 128,000, the maximum analog I/O is 4000, and the maximum total I/O is 128,000.

What current draw and power dissipation should be planned for this controller?

Current draw is 1200 mA at 5.1V DC and 14 mA at 24V DC; power dissipation is 3.5 W and thermal dissipation is 11.9 BTU/hr.

Where must the 1756-L61S be installed in the chassis?

It is chassis-based and can go in any slot, but the safety partner must be installed in the slot to the immediate right of the primary controller. The pair occupies a slot width of 2, with each module being one slot.

Which programming software version is required?

RSLogix 5000 programming software, version 18 or later.

What enclosure type rating does the 1756-L61S have?

The enclosure type rating is None (open-style).

User memory
2 MB
Safety memory
1 MB
I/O memory
478 KB
Optional nonvolatile memory storage
128 MB (1784-CF128)
Digital I/O, max
128,000
Analog I/O, max
4000
Total I/O, max
128,000
Current draw @ 5.1V DC
1200 mA
Current draw @ 24V DC
14 mA
Power dissipation
3.5 W
Thermal dissipation
11.9 BTU/hr
Isolation voltage
30V (continuous), Basic Insulation Type, RS-232 to system; Compliant and tested according to IEC/UL 61010-1
Weight, approx (product weight as published)
0.32 kg (0.70 lb)
Slot width
2 (both modules needed; each is one slot)
Module location
Chassis-based, any slot (the safety partner must be installed in the slot to the immediate right of the primary controller)
Wire category
2 - on RS-232 port
North American temperature code
T4A
Enclosure type rating
None (open-style)
RSLogix 5000 programming software
Version 18 or later

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp