Allen-Bradley 1756-IA8D ControlLogix digital input module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1756-IA8D ControlLogix digital input module
  • Device type: ControlLogix digital input module; Inputs: 8 diagnostic inputs, 4 points per group
  • Voltage category / operating range: 79–132 V AC, 47–63 Hz

Specification

Allen-Bradley 1756-IA8D — ControlLogix digital input module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1756-IA8D
Device typeControlLogix digital input module
Inputs8 diagnostic inputs, 4 points per group
Voltage category / operating range79–132 V AC, 47–63 Hz

Ordering & Compatibility

Match the exact voltage category, input wiring and isolation grouping before ordering.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1756-IA8D Procurement Questions

What is the operating voltage range of the 1756-IA8D?

The operating voltage range is 79…132V AC, 47…63 Hz.

How many inputs does the 1756-IA8D provide and how are they grouped?

It provides eight diagnostic inputs, arranged as 4 points/group.

What input delay times apply from screw to backplane?

Off to On: hardware delay 10 ms max + filter time, with user-selectable filter time of 1 ms or 2 ms. On to Off: hardware delay 8 ms max + filter time, with user-selectable filter time of 9 ms or 18 ms.

What isolation does the 1756-IA8D provide?

Isolation voltage is 125V (continuous), basic insulation type, inputs to backplane, and input group-to-group. There is no isolation between individual group inputs.

What are the current draw and backplane power figures?

Current draw is 100 mA @ 5.1V and 3 mA @ 24V; total backplane power is 0.58 W.

What diagnostic capabilities does the module support?

Open wire is detected by off-state leakage current 1.5 mA min, loss of power has a transition range of 46…85V AC, and the time stamp of diagnostics is ±1 ms.

Open wire
Off-state leakage current 1.5 mA min
Loss of power
Transition range 46…85V AC
Time stamp of diagnostics
±1 ms
Inputs
Eight diagnostic (4 points/group)
Operating voltage range
79…132V AC, 47…63 Hz
Input delay time (screw to backplane) — Off to On
Hardware delay: 10 ms max + filter time; User-selectable filter time: 1 ms or 2 ms
Input delay time (screw to backplane) — On to Off
Hardware delay: 8 ms max + filter time; User-selectable filter time: 9 ms or 18 ms
Current draw @ 5.1V
100 mA
Current draw @ 24V
3 mA
Total backplane power
0.58 W
Power dissipation, max
4.5 W @ 60 °C (140 °F)
Thermal dissipation
15.35 BTU/hr
Off-state voltage, max
20V
Off-state current, max
2.5 mA
On-state current, min
5 mA @ 74V AC
On-state current, max
16 mA @ 132V AC
Inrush current, max
250 mA
Input impedance, max
8.25 kΩ @ 132V AC, 60 Hz
Cyclic update time
200 µs…750 ms
Change of state
Software configurable
Time stamp of inputs
±200 µs
Isolation voltage
125V (continuous), basic insulation type, inputs to backplane, and input group-to-group No isolation between individual group inputs
Module keying
Electronic, software configurable
RTB keying
User-defined mechanical
Slot width
1
Wire category
1(2) - on signal ports
Enclosure type
None (open-style)
North American temperature code
T4A

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP