Allen-Bradley 1756-IN16 ControlLogix digital input module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1756-IN16 ControlLogix digital input module
  • Device type: ControlLogix digital input module; Inputs: 16 inputs, 8 points per group
  • Voltage category / operating range: 24 V AC category; 10–30 V AC, 47–63 Hz

Specification

Allen-Bradley 1756-IN16 — ControlLogix digital input module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1756-IN16
Device typeControlLogix digital input module
Inputs16 inputs, 8 points per group
Voltage category / operating range24 V AC category; 10–30 V AC, 47–63 Hz

Ordering & Compatibility

Match the exact voltage category, input wiring and isolation grouping before ordering.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1756-IN16 Procurement Questions

How many inputs does the 1756-IN16 provide and how are they grouped?

The module provides 16 inputs arranged as 8 points/group.

What input voltage does the 1756-IN16 accept?

The voltage category is 24V AC 50/60 Hz, and the operating voltage range is 10…30V AC, 47…63 Hz.

What are the input delay times for Off-to-On and On-to-Off transitions?

For Off to On, the hardware delay is 10 ms max plus filter time, with user-selectable filter time of 0 ms, 1 ms, or 2 ms. For On to Off, the hardware delay is 10 ms max plus filter time, with user-selectable filter time of 9 ms or 18 ms.

What isolation is provided between inputs and the backplane?

Isolation voltage is 250V (continuous), basic insulation type, inputs-to-backplane and input group-to-group. There is no isolation between individual group inputs.

What are the current draw and backplane power requirements?

Current draw is 135 mA at 5.1V and 2 mA at 24V, with total backplane power of 0.56 W.

What on-state and off-state current limits apply?

On-state current minimum is 5 mA @ 10V AC, 60 Hz and maximum is 21 mA @ 30V AC, 60 Hz. Off-state current maximum is 2.75 mA.

Inputs
16 (8 points/group)
Voltage category
24V AC 50/60 Hz
Operating voltage range
10…30V AC, 47…63 Hz
Input voltage, nom
24V AC 50/60 Hz
Voltage and current ratings
Backplane: 5.1V DC, 135 mA; 24V DC, 2 mA; Inputs: 10…30V AC, 50/60Hz 25 mA max
Input delay time (screw to backplane) — Off to On
Hardware delay: 10 ms max + filter time User-selectable filter time: 0 ms, 1 ms, or 2 ms
Input delay time (screw to backplane) — On to Off
Hardware delay: 10 ms max + filter time User-selectable filter time: 9 ms or 18 ms
Current draw @ 5.1V
135 mA
Current draw @ 24V
2 mA
Total backplane power
0.56 W
Power dissipation, max
5.1 W @ 60 °C (140 °F)
Thermal dissipation
17.39 BTU/hr
Off-state voltage, max
5V
Off-state current, max
2.75 mA
On-state current, min
5 mA @ 10V AC, 60 Hz
On-state current, max
21 mA @ 30V AC, 60 Hz
Inrush current, max
250 mA
Input impedance, max
2.5 kΩ @ 30V AC, 60 Hz
Cyclic update time
200 µs…750 ms
Change of state
Software configurable
Time stamp of inputs
±200 µs
Isolation voltage
250V (continuous), basic insulation type, inputs-to-backplane, and input group-to-group No isolation between individual group inputs
Module keying
Electronic, software configurable
RTB keying
User-defined mechanical
Slot width
1
Wire category
1 - on signal ports
Enclosure type
None (open-style)
Temperature code
T3

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP