Allen-Bradley 1756-OA16 ControlLogix digital output module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1756-OA16 ControlLogix digital output module
  • Device type: ControlLogix digital output module; Outputs: 16 outputs, 8 points per group
  • Voltage category / operating range: 120/240 V AC category; 74–265 V AC, 47–63 Hz

Specification

Allen-Bradley 1756-OA16 — ControlLogix digital output module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1756-OA16
Device typeControlLogix digital output module
Outputs16 outputs, 8 points per group
Voltage category / operating range120/240 V AC category; 74–265 V AC, 47–63 Hz

Ordering & Compatibility

Check the exact output voltage, isolation arrangement and terminal block before replacing a module.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1756-OA16 Procurement Questions

What load current range does the 1756-OA16 support per point?

The minimum load current is 10 mA per point, and the maximum current per point is 0.5 A @ 60 °C (140 °F).

What commutating voltage limits apply to the 1756-OA16 outputs?

Per footnote (2), the commutating dv/dt of the output voltage (OUTPUT to L2) should not exceed 0.2V/µs for loads under 50 mA; the 4V/µs maximum rating applies to the higher load segment defined in footnote (2) (OUTPUT to L2).

How are the outputs fused and grouped?

The module has 16 mechanically fused outputs at 8 points per group, with one fuse and indicator per group. Fusing is mechanically fused/group, 3.15 A @ 250V AC slow blow, 1500 A interruption current, Littelfuse p/n H2153.15.

What surge current can a point and a group withstand?

Surge current per point is 5 A for 43 ms per point, repeatable every 2 s @ 60 °C (140 °F); surge current per group is 15 A for 43 ms per group, repeatable every 2 s @ 60 °C (140 °F).

What output states can be configured in Fault and Program modes?

Per point, both Fault mode and Program mode can be set to Hold last state, On or Off, with Off as the default.

Which removable terminal blocks and wire sizes are specified?

The removable terminal block options are 1756-TBNH and 1756-TBSH. For 1756-TBNH, single wire connection is 0.33…2.1 mm2 (22…14 AWG) and double wire connection is 0.33…1.3 mm2 (22…16 AWG); for 1756-TBSH, single wire connection is 0.33…2.1 mm2 (22…14 AWG), all with 1.2 mm (3/64 in.) insulation max.

Time stamp of diagnostics
±1 ms
Fuse blown
One fuse and indicator/group
Outputs
16 mechanically fused/group (8 points/group)
Pilot duty
0.5 A
Voltage category
120/240V AC 50/60 Hz
Operating voltage range
74…265V AC, 47…63 Hz
Output delay time — Off to On
11 ms @ 50 Hz; 9.3 ms @ 60 Hz
Output delay time — On to Off
11 ms @ 50 Hz; 9.3 ms @ 60 Hz
Current draw @ 5.1V
400 mA
Current draw @ 24V
2 mA
Total backplane power
2.1 W
Power dissipation, max
6.5 W @ 60 °C (140 °F)
Thermal dissipation
22.17 BTU/hr
Off-state leakage current, max
3 mA per point
On-state voltage drop, max
1.5V @ 0.5 A; 5.7V @ load current < 50 mA
Current per point, max
0.5 A @ 60 °C (140 °F)
Current per group, max
2 A @ 60 °C (140 °F)
Current per module, max
4 A @ 60 °C (140 °F)
Surge current per point
5 A for 43 ms per point, repeatable every 2 s @ 60 °C (140 °F)
Surge current per group
15 A for 43 ms per group, repeatable every 2 s @ 60 °C (140 °F)
Load current, min
10 mA per point
Commutating voltage
4V/µs for loads > 50 mA; 0.2V/µs for loads < 50 mA(2)
Scheduled outputs
Synchronization within 16.7 s max, reference to the Coordinated System Time
States in Fault mode per point
Hold last state, On or Off (Off is default)
States in Program mode per point
Hold last state, On or Off (Off is default)
Isolation voltage
250V (continuous), basic insulation type, outputs to backplane, and group to group
Inhibit voltage, max
Zero crossing 60V peak
Module keying
Electronic, software configurable
Fusing
Mechanically fused/group, 3.15 A @ 250V AC slow blow, 1500 A interruption current, Littelfuse p/n H2153.15
RTB keying
User-defined mechanical
Slot width
1
Wire size
1756-TBNH Single wire connection: 0.33…2.1 mm2 (22…14 AWG) solid or stranded shielded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max. Double wire connection: 0.33…1.3 mm2 (22…16 AWG) solid or stranded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max. 1756-TBSH Single wire connection: 0.33…2.1 mm2 (22…14 AWG) solid or stranded shielded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max.
Wire category
1 - on signal ports
Enclosure type
None (open style)
North American temperature code
T4

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp