Allen-Bradley 1756-IB16IF ControlLogix digital input module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1756-IB16IF ControlLogix digital input module
  • Device type: ControlLogix digital input module; Inputs: 16 individually isolated inputs
  • Voltage category / operating range: 12/24 V DC sink/source; 10–30 V DC

Specification

Allen-Bradley 1756-IB16IF — ControlLogix digital input module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1756-IB16IF
Device typeControlLogix digital input module
Inputs16 individually isolated inputs
Voltage category / operating range12/24 V DC sink/source; 10–30 V DC

Ordering & Compatibility

Match the exact voltage category, input wiring and isolation grouping before ordering.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1756-IB16IF Procurement Questions

How many inputs does the 1756-IB16IF provide, and are they isolated from one another?

The module provides 16 individually isolated inputs.

What input voltage does the 1756-IB16IF accept?

It is in the 12/24V DC sink/source voltage category, with an operating voltage range of 10…30V DC and a nominal input voltage of 24V DC.

What input delay and filter time can be configured?

Both Off-to-On and On-to-Off input delay (screw to backplane) are 14 µs nom/23 µs max plus a user-configurable filter time of 0…30,000 µs.

What are the off-state and on-state current limits?

Off-state current max is 1.5 mA with off-state voltage max 5V; on-state current min is 2 mA @ 10V DC and on-state current max is 5 mA @ 30V DC.

What backplane current and power does the module draw?

Current draw is 275 mA @ 5.1V and 3 mA @ 24V, with total backplane power of 1.47 W and power dissipation of 3.8 W @ 60 °C (140 °F).

What isolation is specified for the inputs?

Isolation voltage is 250V (continuous), reinforced insulation type, inputs-to-backplane, and 250V (continuous), basic insulation type, input-to-input.

Inputs
16 individually isolated
Voltage category
12/24V DC sink/source
Operating voltage range
10…30V DC
Input voltage, nom
24V DC
Input delay time (screw to backplane) — Off to On
14 µs nom/23 µs max + user-configurable filter time of 0…30,000 µs
Input delay time (screw to backplane) — On to Off
14 µs nom/23 µs max + user-configurable filter time of 0…30,000 µs
Current draw @ 5.1V
275 mA
Current draw @ 24V
3 mA
Total backplane power
1.47 W
Power dissipation
3.8 W @ 60 °C (140 °F)
Thermal dissipation
12.97 BTU/hr
Off-state voltage, max
5V
Off-state current, max
1.5 mA
On-state current, min
2 mA @ 10V DC
On-state current, max
5 mA @ 30V DC
Input impedance, max
6 kΩ @ 30V DC
Cyclic update time
200 µs…750 ms
Change of state
Software configurable
Time stamp of inputs
± 4 µs for inputs < 4 kHz; ± 13 µs for inputs > 4 kHz
Isolation voltage
250V (continuous), reinforced insulation type, inputs-to-backplane 250V (continuous), basic insulation type, input-to-input
Module keying
Electronic, software configurable
RTB keying
User-defined mechanical
Slot width
1
Wire category
1 on signal ports(1)
Enclosure type
None (open-style)
Temperature code
T4
Reverse polarity protection
Yes

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp