Allen-Bradley 1756-OB16IEF ControlLogix digital output module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1756-OB16IEF ControlLogix digital output module
  • Device type: ControlLogix digital output module; Outputs: 16 individually isolated outputs
  • Voltage category / operating range: 12/24 V DC sink/source; 10–30 V DC

Specification

Allen-Bradley 1756-OB16IEF — ControlLogix digital output module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1756-OB16IEF
Device typeControlLogix digital output module
Outputs16 individually isolated outputs
Voltage category / operating range12/24 V DC sink/source; 10–30 V DC

Ordering & Compatibility

Check the exact output voltage, isolation arrangement and terminal block before replacing a module.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1756-OB16IEF Procurement Questions

What is the operating voltage range and voltage category of the 1756-OB16IEF?

The voltage category is 12/24V DC sink/source, and the operating voltage range is 10…30V DC.

How many outputs does this module provide and how are they isolated?

It provides 16 individually isolated outputs.

What are the output delay times from backplane to screw?

Off to On is 14 µs nom/23 µs max, and On to Off is 14 µs nom/23 µs max.

What PWM timing does the module support?

PWM cycle time is 1 ms min/1 hour max, PWM On time is 200 µs min/1 hour max, and PWM On time accuracy is ± 20 µs.

What are the current per point and current per module limits?

Current per point, max is 2 A @ 45 °C (113 °F) 4 channels max or 1 A @ 60 °C (140 °F). Current per module, max is 16 A @ 60 °C (140 °F) 1 A max per channel or 8 A @ 45 °C (113 °F) 2 A max per channel.

How does the module behave in Fault mode and Program mode?

In Fault mode per point, states are Hold last state, On or Off (Off is default); duration is 1, 2, 5, 10 s, Forever (Forever is default); final state after Fault mode duration is On or Off (default is Off). In Program mode per point, states are Hold last state, On or Off (default is Off).

Outputs
16 individually isolated
Pilot duty
4 A inrush
Voltage category
12/24V DC sink/source
Operating voltage range
10…30V DC
Output delay time (backplane to screw) — Off to On
14 µs nom/23 µs max
Output delay time (backplane to screw) — On to Off
14 µs nom/23 µs max
PWM cycle time
1 ms min/1 hour max
PWM On time
200 µs min/1 hour max
PWM On time accuracy
± 20 µs
Current draw @ 5.1V
320 mA
Current draw @ 24V
3 mA
Total backplane power
1.7 W
Power dissipation
4.9 W max (16 channels @ 1 A or 4 channels @ 2 A)
Thermal dissipation
16.71 BTU/hr
Off-state leakage current per point, max
< 0.1 mA per point
On-state voltage drop, max
0.2V DC @ 1 A; 0.4V DC @ 2 A
Current per point, max
2 A @ 45 °C (113 °F) 4 channels max; 1 A @ 60 °C (140 °F)
Current per module, max
16 A @ 60 °C (140 °F) 1 A max per channel; 8 A @ 45 °C (113 °F) 2 A max per channel
Surge current per point
4 A for 10 ms per point, repeatable every 2 s
Load current, min
1 mA per point
Scheduled outputs
CIP Sync™ only
States in Fault mode per point
Hold last state, On or Off (Off is default)
Duration of Fault mode per point
1, 2, 5, 10 s, Forever (Forever is default)
Final state after Fault mode duration per point
On or Off (default is Off)
States in Program mode per point
Hold last state, On or Off (default is Off)
Isolation voltage
250V (continuous), reinforced insulation type, outputs-to-backplane 250V (continuous), basic insulation type, output-to-output
Module keying
Electronic, software configurable
Fusing
Electronically fused per point
Reverse polarity protection
No
RTB keying
User-defined mechanical
Slot width
1
Wire category
1 on signal ports(1)
Enclosure type
None (open-style)
Temperature code
T4

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp