Allen-Bradley 1746-OB16E Digital Output Module

Series#: AllenBradley

Product Details

  • 1746-OB16E – High-performance Sink/Source DC Output Module for Allen-Bradley SLC 500 Systems.
  • 16 discrete output channels with 24V DC operation, ideal for industrial automation control.
  • Built-in electronic short-circuit protection and fuse-less design for enhanced reliability.
  • Compact form factor with easy installation in any SLC 500 chassis slot.
  • Supported by RSLogix 500 and all common industrial networks (DH+, RIO, Ethernet).

Specification

The Allen-Bradley 1746-OB16E is a robust 16-point DC output module designed for the SLC 500 programmable controller family. Engineered for demanding industrial environments, this module provides 24V DC sink/source outputs with built-in protection against overcurrent and short circuits. The 1746-OB16E is a direct replacement for older modules and offers seamless integration into existing SLC 500 systems, supporting both 24V DC and 5V DC logic levels. Its compact design and high-density output channels make it ideal for controlling solenoids, relays, and indicator lights in discrete manufacturing, process control, and material handling applications. Each output is optically isolated from the backplane, ensuring noise immunity and reliable operation in electrically noisy environments.

Parameter Value
Product Type Discrete DC Output Module
Number of Outputs 16 (sink/source, 24V DC)
Output Voltage Range 20.4 to 26.4V DC
Output Current per Channel 0.5 A (continuous), 3 A (peak, 10 ms)
Total Output Current (Module) 8 A (max, continuous)
Logic Supply Voltage 5V DC (from backplane)
Power Dissipation 4.5 W (max, all outputs on)
Isolation Optical isolation between outputs and backplane (1500V AC for 1 minute)
Protection Electronic short-circuit protection, overcurrent shutdown (self-resetting)
Indication Green LED per output for ON status, red LED for fault
Operating Temperature 0 to 60°C (32 to 140°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Humidity 5% to 95% non-condensing
Vibration Resistance 5 to 500 Hz, 2 g peak
Shock Resistance 15 g peak (11 ms half-sine)
Backplane Current Draw 75 mA (5V DC), 0 mA (24V DC)
Wire Size 14 AWG to 22 AWG (2.5 mm² to 0.34 mm²)
Mounting Any slot in SLC 500 chassis (1746-A series)
Compatible Processors SLC 5/01, 5/02, 5/03, 5/04, 5/05
Approvals UL, cUL, CE, ATEX (Zone 2), RoHS
Weight 0.2 kg (0.44 lb)
Dimensions (H x W x D) 94 x 50 x 87 mm (3.7 x 2.0 x 3.4 in)

Allen-Bradley 1746-OB16E Digital Output Module

What is the difference between the 1746-OB16E and a non-protected sourcing output module?

The 1746-OB16E is electronically protected: protection is based on a thermal cut-out principle, and on a short circuit or overload the affected channel limits current within milliseconds after its thermal cut-out temperature is reached while all other channels continue to operate as directed by the CPU (processor) module. This electronic protection is what distinguishes the E variant from 1746-OB16.

What happens to an output channel during an overload, and how is it indicated?

The module performs auto-reset under overload conditions: while in current limit the output channel can cool below the thermal cut-out temperature, allowing the module to auto-reset and resume control of the output channel as directed by the processor. On a short circuit or overload the E-FUSE LED indicator illuminates provided power is applied to the module (5V dc via the backplane and load power via an external supply).

How much current can each point and the module carry, and at which temperatures?

Continuous current per point is 1.0 A at 30 °C (86 °F) and 0.50 A at 60 °C (140 °F); continuous current per module is 8.0 A at 0...60 °C (32...140 °F).

What are the switching delays and the surge rating per point?

Signal delay at maximum resistive load is On = 1.0 ms and Off = 1.0 ms. Surge current per point is 2.0 A for 10 ms, and the table footnote states surge current = 32 A per module for 10 ms.

Does this module support fast turn-off for inductive loads?

Fast turn-off applies to 1746-OB16E Series B and later, which provides fast OFF delay for inductive loads. Comparative OFF delay times when switching a Bulletin 100-B110 (24W sealed) contactor are 152 ms for 1746-OB8/1746-OV8 versus 47 ms for the fast turn-off modules.

What are the general environmental and isolation specifications for this module?

General I/O specifications for the modules covered by the document include operating temperature 0...60 °C (32...140 °F), storage temperature -40...85 °C (-40...185 °F), operating humidity 5...95% (noncondensing), and noise immunity to NEMA standard ICS 2-230. Isolation is 1500V, electro-optical between I/O terminals and control logic.

Register posture - text-extraction failure only (evidence review pending), NOT an identity hold; full binding with posture disclosed
Register entry for goods 870: title "Allen-Bradley 1746-OB16E Digital Output Module", model_candidate "1746-OB16E", category text_extraction_failed, original_job_status evidence_review_pending. The posture is an acquisition/extraction failure only ("Original PDF exists but usable text is absent; original page/OCR review required"), not a supplier-identity hold, so full binding proceeds with the posture disclosed.
Catalog-number attestation - 1746-OB16E listed among the Output Module Catalog Numbers inside the manufacturer document itself
The installation instructions list 1746-OB16E among the Output Module Catalog Numbers for the digital I/O modules covered by the document; the exact catalog string 1746-OB16E is attested inside the manufacturer document itself, not taken from the catalog-linked lead filename.
Outputs and points per common - 16 outputs, 16 points per common (dedicated 1746-OB16E column)
1746-OB16E has 16 outputs and 16 points per common (the table columns run 1746-OB8, 1746-OB16, 1746-OB16E in that order).
Voltage category - 24V dc Signal Output (single value printed across the whole specifications table)
Voltage category: 24V dc Signal Output (single value printed across the whole specifications table).
Operating voltage - 10...30 V dc (source) for the E variant (the 10...50 cell belongs to the other modules and is not bound)
Operating voltage for the E variant: 10...30 V dc (source) - the second cell of the row; the 10...50 (source) cell in the same row belongs to the other modules in the table and is not bound to this record.
Backplane current consumption - 0.135 A at 5V dc and 0.0 A at 24V dc (E-variant column)
Backplane current consumption of the E variant: 0.135 A at 5V dc and 0.0 A at 24V dc (third column; the middle column draws 0.280 A at 5V dc and is not bound).
Signal delay, max. resistive load - On = 1.0 ms, Off = 1.0 ms (E-variant column)
Signal delay, max. resistive load, for the E variant: On = 1.0 ms, Off = 1.0 ms (third column; the other two columns print On = 0.1 ms).
Off-state leakage, max. 1 mA; load current, min. 1 mA (single values printed across the whole table)
Off-state leakage, max.: 1 mA; load current, min.: 1 mA (single values printed across the whole specifications table).
Continuous current per point - 1.0 A at 30 °C (86 °F) and 0.50 A at 60 °C (140 °F) (E-variant column)
Continuous current per point, E-variant column: 1.0 A at 30 °C (86 °F) and 0.50 A at 60 °C (140 °F).
Continuous current per module - 8.0 A at 0...60 °C (32...140 °F) (E-variant column)
Continuous current per module, E-variant column: 8.0 A at 0...60 °C (32...140 °F).
On-state voltage drop, max. - 1.0V at 0.50 A (E-variant column)
On-state voltage drop, max., E-variant column: 1.0V at 0.50 A.
Surge current per point - 2.0 A for 10 ms (E-variant column)
Surge current per point, E-variant column: 2.0 A for 10 ms.
Surge-current footnote - surge current = 32 A per module for 10 ms
Footnote to the specifications table: surge current = 32 A per module for 10 ms.
Removable terminal block; ID code 2920 for configuration with programming software or the HHT
1746-OB16E has a removable terminal block (footnote marker on its table column), and its ID code for configuration with programming software or the HHT is 2920.
Fast turn-off - 1746-OB16E Series B and later; comparative OFF delay 47 ms vs 152 ms switching a Bulletin 100-B110 contactor
1746-OB16E Series B and later is a fast turn-off module providing fast OFF delay for inductive loads; comparative OFF delay times when switching a Bulletin 100-B110 (24W sealed) contactor are 152 ms for 1746-OB8/1746-OV8 versus 47 ms for the fast turn-off modules.
Electronic protection - thermal cut-out principle; protects from short circuit and overload; the feature distinguishing the E variant from 1746-OB16
The electronic protection of the 1746-OB16E is designed to protect the module from short circuit and overload current conditions and is based on a thermal cut-out principle: on a short circuit or overload, the affected channel limits current within milliseconds after its thermal cut-out temperature is reached, and all other channels continue to operate as directed by the CPU (processor) module. This electronic protection is what distinguishes the E variant from 1746-OB16.
Short-circuit/overload diagnostics - E-FUSE LED illuminates provided power is applied to the module
On a short circuit or overload current condition, the module E-FUSE LED indicator illuminates provided power is applied to the module (5V dc via the backplane and load power via an external supply).
Auto-reset operation - under overload the channel can cool below the thermal cut-out temperature and the module auto-resets
The 1746-OB16E performs auto-reset under overload conditions: while in current limit, the output channel can cool below the thermal cut-out temperature, allowing the module to auto-reset and resume control of the output channel as directed by the processor.
Wiring-diagram group - transistor output-sourcing; 1746-OB16E wired at 10...30V dc
The wiring diagram group for 1746-OB16, 1746-OB16E and 1746-OBP16 is headed, in that order, 10...50V dc, 10...30V dc, 20.4...26.4V dc, transistor output-sourcing: the 1746-OB16E is a sourcing transistor output wired at 10...30V dc.
Wiring-diagram variant label - "10-30V dc (OB16E)" (exact-string attestation inside the document)
The same wiring diagram labels the variant explicitly as 10-30V dc (OB16E).
Heat dissipation - 0.150 W per point, 0.675 W minimum, 3.07 W total (dedicated 1746-OB16E row; selection-guide worksheet divergence flagged, not resolved - see flags)
Heat dissipation for 1746-OB16E: 0.150 W per point, 0.675 W minimum, 3.07 W total (dedicated 1746-OB16E row; the 1746-OB16 row, 0.388 / 1.400 / 7.60, is not bound).
General I/O specifications (all modules covered by the document) - operating 0...60 °C, storage -40...85 °C, humidity 5...95% noncondensing, NEMA ICS 2-230 noise immunity
General I/O specifications printed for all modules covered by the document, including this one: operating temperature 0...60 °C (32...140 °F), storage temperature -40...85 °C (-40...185 °F), operating humidity 5...95% (noncondensing), noise immunity NEMA standard ICS 2-230.
General I/O specifications (all modules covered by the document) - vibration 0.015 in. peak / 2.5 g, operating shock 30 g, isolation 1500V, UL/CSA/CE/C-Tick, Class I Division 2
General I/O specifications printed for all modules covered by the document, including this one: operating vibration displacement 0.015 in. peak at 5...57 Hz and acceleration 2.5 g at 57...2000 Hz; operating shock 30 g (the value for all modules except relay contact modules; this module is a transistor-output module); isolation 1500V, electro-optical between I/O terminals and control logic; agency certification UL listed, CSA certified or C-UL approved, CE compliant, C-Tick marked; hazardous environment class Class I, Division 2.
Revision corroboration - 1746-IN027D-EN-P (December 2012) prints the same 1746-OB16E column values; the two revisions agree, no divergence
The current revision of the same publication prints the same 1746-OB16E column values bound here: 16 outputs, 16 points per common, operating voltage 10...30 (source), backplane current 0.135 A at 5V DC and 0.0 A at 24V DC. The two revisions agree; no divergence.
Selection-guide corroboration - 1747-SG001B-EN-P states the 1746-OB16E provides electronic protection from short circuit and overload conditions
The SLC Systems Selection Guide likewise states that the 1746-OB16E, -OB6EI, and -OB32E modules provide electronic protection from short circuit and overload conditions.

Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp