Allen-Bradley 1756-OB32 ControlLogix digital output module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1756-OB32 ControlLogix digital output module
  • Device type: ControlLogix digital output module; Outputs: 32 outputs, 16 points per group
  • Voltage category / operating range: 12/24 V DC sourcing; 10–31.2 V DC

Specification

Allen-Bradley 1756-OB32 — ControlLogix digital output module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1756-OB32
Device typeControlLogix digital output module
Outputs32 outputs, 16 points per group
Voltage category / operating range12/24 V DC sourcing; 10–31.2 V DC

Ordering & Compatibility

Check the exact output voltage, isolation arrangement and terminal block before replacing a module.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1756-OB32 Procurement Questions

How many outputs does the 1756-OB32 provide, and how are they grouped?

The module provides 32 outputs, arranged as 16 points per group.

What operating voltage range does the 1756-OB32 accept?

It is a 12/24V DC source module with an operating voltage range of 10…31.2V DC.

What are the maximum current ratings per point and per module?

Current per point, max is 0.35 A @ 60 °C (140 °F) and 0.5 A @ 50 °C (122 °F) linear derating; current per module, max is 10 A @ 60 °C (140 °F) and 16 A @ 50 °C (122 °F) linear derating.

What output delay times should I expect for Off to On and On to Off transitions?

Off to On is 60 µs nom/1 ms max, and On to Off is 200 µs nom/1 ms max.

Is the 1756-OB32 protected against output faults, and which terminal blocks are used for agency-certified systems?

The module is not protected; a fused IFM can be used to help protect outputs. The ControlLogix system has been agency certified using only the ControlLogix RTBs 1756-TBCH, 1756-TBNH, 1756-TBSH, and 1756-TBS6H, and applications using other wiring termination methods can require application-specific approval by the certifying agency.

What isolation is provided between outputs and backplane, and between output groups?

Isolation voltage is 250V (continuous), basic insulation type, outputs to backplane, and 125V (continuous), basic insulation type, outputs group to group, with no isolation between individual outputs.

Outputs
32 (16 points/group)
Voltage category
12/24V DC source
Operating voltage range
10…31.2V DC
Output delay time — Off to On
60 µs nom/1 ms max
Output delay time — On to Off
200 µs nom/1 ms max
Current draw @ 5.1V
300 mA
Current draw @ 24V
2 mA
Total backplane power
1.58 W
Power dissipation, max
4.8 W @ 60 °C (140 °F)
Thermal dissipation
16.37 BTU/hr
Off-state leakage current per point, max
0.5 mA per point
On-state voltage drop, max
200 mV DC @ 0.5 A
Current per point, max
0.35 A @ 60 °C (140 °F); 0.5 A @ 50 °C (122 °F) linear derating
Current per module, max
10 A @ 60 °C (140 °F); 16 A @ 50 °C (122 °F) linear derating
Surge current per point, max
1 A for 10 ms per point, repeatable every 2 s @ 60 °C (140 °F)
Load current, min
3 mA per point
Scheduled outputs
Synchronization within 16.7 s max, reference to the Coordinated System Time
States in Fault mode per point
Hold last state, On or Off (Off is default)
States in Program mode per point
Hold last state, On or Off (Off is default)
Isolation voltage
250V (continuous), basic(1) insulation type, outputs to backplane. 125V (continuous), basic insulation type, outputs group to group. No isolation between individual outputs.
Module keying
Electronic, software configurable
Fusing
Not protected. A fused IFM can be used to help protect outputs. See publication 1492-TD008. However, the ControlLogix system has been agency certified using only the ControlLogix RTBs, that is, 1756-TBCH, 1756-TBNH, 1756-TBSH, and 1756-TBS6H. Any application that requires agency certification of the ControlLogix system that uses other wiring termination methods can require application-specific approval by the certifying agency.
RTB keying
User-defined mechanical
Slot width
1
Wire category
1(2)
Enclosure type
None (open-style)
Temperature code
T4

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp