1756-OB32 Procurement Questions
How many outputs does the 1756-OB32 provide, and how are they grouped?
The module provides 32 outputs, arranged as 16 points per group.
What operating voltage range does the 1756-OB32 accept?
It is a 12/24V DC source module with an operating voltage range of 10…31.2V DC.
What are the maximum current ratings per point and per module?
Current per point, max is 0.35 A @ 60 °C (140 °F) and 0.5 A @ 50 °C (122 °F) linear derating; current per module, max is 10 A @ 60 °C (140 °F) and 16 A @ 50 °C (122 °F) linear derating.
What output delay times should I expect for Off to On and On to Off transitions?
Off to On is 60 µs nom/1 ms max, and On to Off is 200 µs nom/1 ms max.
Is the 1756-OB32 protected against output faults, and which terminal blocks are used for agency-certified systems?
The module is not protected; a fused IFM can be used to help protect outputs. The ControlLogix system has been agency certified using only the ControlLogix RTBs 1756-TBCH, 1756-TBNH, 1756-TBSH, and 1756-TBS6H, and applications using other wiring termination methods can require application-specific approval by the certifying agency.
What isolation is provided between outputs and backplane, and between output groups?
Isolation voltage is 250V (continuous), basic insulation type, outputs to backplane, and 125V (continuous), basic insulation type, outputs group to group, with no isolation between individual outputs.
- Outputs
- 32 (16 points/group)
- Voltage category
- 12/24V DC source
- Operating voltage range
- 10…31.2V DC
- Output delay time — Off to On
- 60 µs nom/1 ms max
- Output delay time — On to Off
- 200 µs nom/1 ms max
- Current draw @ 5.1V
- 300 mA
- Current draw @ 24V
- 2 mA
- Total backplane power
- 1.58 W
- Power dissipation, max
- 4.8 W @ 60 °C (140 °F)
- Thermal dissipation
- 16.37 BTU/hr
- Off-state leakage current per point, max
- 0.5 mA per point
- On-state voltage drop, max
- 200 mV DC @ 0.5 A
- Current per point, max
- 0.35 A @ 60 °C (140 °F); 0.5 A @ 50 °C (122 °F) linear derating
- Current per module, max
- 10 A @ 60 °C (140 °F); 16 A @ 50 °C (122 °F) linear derating
- Surge current per point, max
- 1 A for 10 ms per point, repeatable every 2 s @ 60 °C (140 °F)
- Load current, min
- 3 mA per point
- Scheduled outputs
- Synchronization within 16.7 s max, reference to the Coordinated System Time
- States in Fault mode per point
- Hold last state, On or Off (Off is default)
- States in Program mode per point
- Hold last state, On or Off (Off is default)
- Isolation voltage
- 250V (continuous), basic(1) insulation type, outputs to backplane. 125V (continuous), basic insulation type, outputs group to group. No isolation between individual outputs.
- Module keying
- Electronic, software configurable
- Fusing
- Not protected. A fused IFM can be used to help protect outputs. See publication 1492-TD008. However, the ControlLogix system has been agency certified using only the ControlLogix RTBs, that is, 1756-TBCH, 1756-TBNH, 1756-TBSH, and 1756-TBS6H. Any application that requires agency certification of the ControlLogix system that uses other wiring termination methods can require application-specific approval by the certifying agency.
- RTB keying
- User-defined mechanical
- Slot width
- 1
- Wire category
- 1(2)
- Enclosure type
- None (open-style)
- Temperature code
- T4
Technical specifications are based on the linked manufacturer references.