Allen-Bradley 1756-OH8I ControlLogix digital output module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1756-OH8I ControlLogix digital output module
  • Device type: ControlLogix digital output module; Outputs: 8 individually isolated outputs
  • Voltage category / operating range: 125 V DC sink/source; 90–146 V DC

Specification

Allen-Bradley 1756-OH8I — ControlLogix digital output module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1756-OH8I
Device typeControlLogix digital output module
Outputs8 individually isolated outputs
Voltage category / operating range125 V DC sink/source; 90–146 V DC

Ordering & Compatibility

Check the exact output voltage, isolation arrangement and terminal block before replacing a module.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1756-OH8I Procurement Questions

How many outputs does the 1756-OH8I provide, and are they isolated?

The module has 8 individually isolated outputs.

What operating voltage range does the 1756-OH8I support?

It is rated for a 125V DC sink/source voltage category with an operating voltage range of 90…146V DC.

What is the maximum current per point and per module?

Current per point is 2 A @ 60 °C (140 °F) max, and current per module is 8 A @ 60 °C (140 °F) max.

Are the outputs fused or protected on the 1756-OH8I?

The outputs are not protected; a fused IFM is recommended to help protect outputs.

What output states can be configured in Fault mode and Program mode?

Per point, both Fault mode and Program mode can be set to Hold last state, On or Off (Off is default).

What is the off-state leakage current and on-state voltage drop?

Off-state leakage current is 1 mA per point max, and on-state voltage drop is 2V DC @ 2 A max.

Outputs
8 individually isolated
Voltage category
125V DC sink/source
Operating voltage range
90…146V DC
Output delay time — Off to On
2 ms max
Output delay time — On to Off
2 ms max
Current draw @ 5.1V
210 mA
Current draw @ 24V
2 mA
Total backplane power
1.11 W
Power dissipation, max
3.3 W @ 60 °C (140 °F)
Thermal dissipation
11.25 BTU/hr
Off-state leakage current, max
1 mA per point
On-state voltage drop, max
2V DC @ 2 A
Current per point, max
2 A @ 60 °C (140 °F)
Current per module, max
8 A @ 60 °C (140 °F)
Surge current per point
4 A for 10 ms per point, repeatable every 1 s @ 60 °C (140 °F)
Load current, min
2 mA per point
Scheduled outputs
Synchronization within 16.7 s max, reference to the Coordinated System Time
States in Fault mode per point
Hold last state, On or Off (Off is default)
States in Program mode per point
Hold last state, On or Off (Off is default)
Isolation voltage
250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output
Module keying
Electronic, software configurable
Fusing
Not protected. A fused IFM is recommended to help protect outputs.
RTB keying
User-defined mechanical
Slot width
1
Wire category
1(1)
Enclosure type
None (open-style)
North American temperature code
T4A

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp