  • Allen-Bradley 1756-IF8H ControlLogix analog input module with HART
  • Device type: ControlLogix analog input module with HART; Channels / wiring: 8 differential voltage/current inputs
  • HART modem arrangement: Series A: one per module; Series B: one per channel; Series A channel isolation: No isolation between individual input channels

Specification

Allen-Bradley 1756-IF8H — ControlLogix analog input module with HART.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1756-IF8H
Device typeControlLogix analog input module with HART
Channels / wiring8 differential voltage/current inputs
HART modem arrangementSeries A: one per module; Series B: one per channel
Series A channel isolationNo isolation between individual input channels

Ordering & Compatibility

Confirm Series A versus Series B; HART modem architecture differs and Series A has no channel-to-channel isolation.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1756-IF8H Procurement Questions

What input ranges does the 1756-IF8H support?

The module supports ±10V; 0…5V; 1…5V; 0…10V; 0…20 mA; 4…20 mA.

How does HART modem allocation differ between series?

Series A has one HART modem per module; Series B has one HART modem per channel. The catalog record does not pin a series, so confirm the series before ordering.

What is the module I/O scan time?

Analog scan time is 18...488 ms (filter dependent). For Series A, typically 1 s per HART channel enabled, with an estimate of 10 s if all 8 channels have HART enabled. For Series B, an estimate of 1 s if all 8 channels have HART enabled, and scan time does not increase with enabling additional channels because one HART modem is assigned per channel.

What can increase the HART update time?

Pass through messages, handheld communicators, secondary masters, communication errors, or configuration changes can significantly increase the update time.

What isolation voltage applies?

Series A: 50V (continuous), Basic insulation type, input channels to backplane, with no isolation between individual input channels. Series B: 250V (continuous), Reinforced Insulation Type, inputs to backplane, and Basic Insulation Type, inputs to ground. The series is not pinned by the catalog record.

What are the overvoltage protection limits?

Overvoltage protection maximum is 30V DC for voltage and 8V DC for current.

Inputs
Series A: Eight differential voltage or current inputs, one HART modem per module; Series B: Eight differential voltage or current inputs, one HART modem per channel
Input range
±10V; 0…5V; 1…5V; 0…10V; 0…20 mA; 4…20 mA
Voltage and current ratings
Backplane: Series A: 5.1V DC, 300 mA, 24V DC, 135 mA; Series B: 5.1V DC, 230 mA, 24V DC, 80 mA; Input voltage range: -10…+10V; Input current range: 0…20 mA, 4…20 mA
Total backplane power
Series A: 4.77 W; Series B: 3.1 W
Power dissipation
Series A: Voltage: 3.21 W, Current: 4.01 W; Series B: Voltage: 3.1 W, Current: 3.9 W
Open circuit detection time
Positive full-scale reading within 5 s
Overvoltage protection, max
Voltage: 30V DC Current: 8V DC
Normal mode noise rejection
Series A: > 80 dB @ 50/60 Hz;; Series B: > 33 dB @ 50 Hz, > 80 dB @ 50/60 Hz
Common mode noise rejection
Series A: > 100 dB @ 50/60 Hz; Series B: > 100 dB @ 50/60 Hz (10 Hz filter)
Calibrated accuracy
Voltage: Better than 0.05% of range; Current: Better than 0.15% of range
Calibration interval
12 months
Offset drift
90 µV/°C
Gain drift with temperature
Voltage: 10 ppm/°C; Current: 20 ppm/°C
Module error
Voltage: 0.1% of range; Current: 0.3% of range
Module I/O scan time
Series A: Analog: 18...488 ms (filter dependent) Typically 1 s per HART channel enabled Estimate 10 s if all 8 channels have HART enabled;; Series B: Analog: 18...488 ms (filter dependent) Estimate 1 s if all 8 channels have HART enabled (scan time does not increase with enabling additional channels because one HART modem is assigned per channel.)
Module HART scan time
Pass through messages, handheld communicators, secondary masters, communication errors, or configuration changes can significantly increase the update time
Data format
IEEE 32-bit floating point
Isolation voltage
Series A: 50V (continuous), Basic insulation type, input channels to backplane; No isolation between individual input channels | Series B: 250V (continuous), Reinforced Insulation Type, inputs to backplane; Basic Insulation Type, inputs to ground
Module keying
Electronic, software configurable
RTB keying
User-defined mechanical
Slot width
1
Wire size
1756-TBCH Single wire connection: 0.33…2.1 mm2 (22…14 AWG) solid or stranded shielded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max. Double wire connection: 0.33…1.3 mm2 (22…16 AWG) solid or stranded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max. 1756-TBS6H Single wire connection: 0.33…2.1 mm2 (22…14 AWG) solid or stranded shielded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max.
Wire category
2 - on signal ports
Wire type
Copper
Enclosure type rating
None (open-style)
Temperature code
T4

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22