Allen-Bradley 1756-LSC8XIB8I ControlLogix low-speed counter module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1756-LSC8XIB8I ControlLogix low-speed counter module
  • Device type: ControlLogix low-speed counter module; Channels / wiring: 8 individually isolated counters plus 8 individually isolated standard/counter-control inputs
  • Maximum counting frequency: 40 kHz

Specification

Allen-Bradley 1756-LSC8XIB8I — ControlLogix low-speed counter module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1756-LSC8XIB8I
Device typeControlLogix low-speed counter module
Channels / wiring8 individually isolated counters plus 8 individually isolated standard/counter-control inputs
Maximum counting frequency40 kHz

Ordering & Compatibility

Distinguish counter inputs from analog measurement channels.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1756-LSC8XIB8I Procurement Questions

How many counters does the 1756-LSC8XIB8I provide, and are they isolated from each other?

The module provides 8 individually isolated counters.

What counting frequency and count range can the module handle?

The maximum counting frequency is 40 kHz, and the count range is 0…2,147,483,648 (31-bit counter).

What input voltage does the module accept?

The voltage category is 12/24V DC sink/source, the operating voltage range is 10…30V DC, and the nominal input voltage is 24V DC.

What are the off-state and on-state current thresholds for the inputs?

Off-state current is a maximum of 1.5 mA, on-state current is a minimum of 2 mA @ 10V DC and a maximum of 5 mA @ 30V DC.

What input delay time applies from screw to backplane?

Both Off to On and On to Off transitions have a delay of 14 µs nom/23 µs max plus a user-configurable filter time of 0…30,000 µs.

What backplane power does the module draw?

Current draw is 275 mA @ 5.1V and 3 mA @ 24V, with total backplane power of 1.47 W.

Number of counters
8 individually isolated
Counting frequency, max
40 kHz
Count range
0…2,147,483,648 (31-bit counter)
Voltage category
12/24V DC sink/source
Operating voltage range
10…30V DC
Off-state voltage, max
5V
Off-state current, max
1.5 mA
On-state current, min
2 mA @ 10V DC
On-state current, max
5 mA @ 30V DC
Change of state
Enter or exit user-configurable windows
Inputs 8
8 individually isolated, standard input or counter-control functionality
Voltage category (inputs)
12/24V DC sink/source
Operating voltage range (inputs)
10…30V DC
Input voltage, nom (inputs)
24V DC
Input delay time (screw to backplane) — Off to On
14 µs nom/23 µs max + user-configurable filter time of 0…30,000 µs
Input delay time (screw to backplane) — On to Off
14 µs nom/23 µs max + user-configurable filter time of 0…30,000 µs
Current draw @ 5.1V
275 mA
Current draw @ 24V
3 mA
Total backplane power
1.47 W
Power dissipation
3.8 W @ 60 °C (140 °F)
Thermal dissipation
12.97 BTU/hr
Input impedance, max
Six k Ω @ 30V DC
Cyclic update time
200 µs…750 ms
Isolation voltage
250V (continuous), reinforced insulation type, inputs-to-backplane 250V (continuous), basic insulation type, input-to-input
Module keying
Electronic, software configurable
RTB keying
User-defined mechanical
Slot width
1
Wire category
1 on signal ports(1)
Enclosure type
None (open-style)
Temperature code
T4
Reverse polarity protection
Yes

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp