Allen-Bradley 1786-RPFS Fiber System Module

Series#: AllenBradley

Product Details

  • 【1786-RPFS】ALLEN-BRADLEY ControlNet Short-Distance Fiber System Module, designed for reliable 0-300m optical transmission.
  • Extends ControlNet over fiber optics up to 300 meters, ideal for noise-immune, long-reach industrial connections.
  • Supports redundant media configurations for enhanced system availability and fault tolerance.
  • Plug-and-play installation with standard ControlNet connectors, compatible with existing Allen-Bradley infrastructure.
  • Rugged industrial design rated for harsh environments, featuring wide operating temperature range.

Specification

The 1786-RPFS is an integral component for expanding ControlNet networks over short-distance fiber optic links, offering robust performance within a 0 to 300-meter range. Designed by Allen-Bradley, this module ensures high-speed, deterministic communication while eliminating electrical noise interference common in copper-based systems. Its optical interface provides galvanic isolation, protecting sensitive control equipment from ground loops and voltage surges. The 1786-RPFS is factory-tested to meet strict industrial standards, making it a trusted choice for critical automation applications in manufacturing, oil and gas, and power generation.

Parameter Specification
Part Number 1786-RPFS
Product Type ControlNet Short-Distance Fiber Module
Network Protocol ControlNet (Allen-Bradley)
Fiber Optic Range 0 to 300 meters
Optical Connector Type ST (bayonet-style) or SMA (depending on variant)
Fiber Core Size 62.5/125 µm (multimode) or 50/125 µm (multimode)
Wavelength 850 nm (typical)
Data Transfer Rate 5 Mbps (ControlNet standard)
Redundancy Support Yes, supports redundant fiber pairs for media redundancy
Power Supply Voltage 24 VDC (from ControlNet tap or backplane)
Power Consumption Typically less than 5 W
Operating Temperature 0°C to 60°C (32°F to 140°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Humidity Range 5% to 95% non-condensing
Enclosure Rating IP20 (open-style, suitable for cabinet mounting)
Dimensions (H x W x D) Approximately 120 mm x 50 mm x 100 mm (4.7 in x 2.0 in x 3.9 in)
Weight Approximately 0.25 kg (0.55 lbs)
Certifications CE, UL, CSA, ATEX (for hazardous locations, if applicable)
Compatibility ControlNet PLCs (e.g., ControlLogix, CompactLogix), Remote I/O, Drives
Installation DIN rail mount or panel mount (via adapter)

Allen-Bradley 1786-RPFS Fiber System Module

What is the maximum fiber distance for the 1786-RPFS?

The 1786-RPFS supports a maximum distance of 300 m (984 ft) for a short-distance fiber link between two ControlNet products.

What fiber type and termination does the 1786-RPFS use?

It uses 200/230 micron HCS (hard-clad silica) fiber with ST termination, operating at a wavelength of 650 nm (red).

What communication rate does the 1786-RPFS support?

The communication rate is 5 Mbps.

What are the power requirements of the 1786-RPFS?

Backplane current is 300 mA @ 5V DC max, and power consumption is 1.5 W max.

What are the bend radius and tension limits for the fiber?

Bend radius is 38 mm (1.5 in.) during installation and 10 mm (0.4 in.) during operation; maximum tension is 490 N (110 lb) during installation and 370 N (85 lb) during operation.

What environmental conditions does the 1786-RPFS tolerate?

Operating temperature is 0…60 °C (32…140 °F), nonoperating temperature is -40…85 °C (-40…185 °F), and relative humidity is 5...95% noncondensing.

Model identity
1786-RPFS
Function / max. distance
short-distance fiber link between two ControlNet products; maximum distance 300 m (984 ft)
Backplane current
Backplane: 300 mA @ 5V DC max
Power consumption
1.5 W max
Power dissipation
1.5 W max
Communication rate
5 Mbps
Fiber type
200/230 micron HCS (hard-clad silica)
TX power, min
(-17 dBm) @ 0…70 °C (32…158 °F) into 200 micron HCS fiber
RX responsivity, min
-21.3 dBm @ 0…70 °C (32…158 °F)
Optical power budget
4.2 dB
Fiber operation wavelength
650 nm (red)
Fiber termination type
ST
Bend radius
38 mm (1.5 in.) during installation; 10 mm (0.4 in.) during operation
Tension, max
490 N (110 lb) during installation; 370 N (85 lb) during operation
Enclosure type rating
None (open-style)
Temperature, operating
0…60 °C (32…140 °F)
Temperature, nonoperating
-40…85 °C (-40…185 °F)
Relative humidity
5...95% noncondensing (as printed, three-dot form)
Vibration
5 g @ 10...500 Hz (as printed, three-dot form)
Shock, operating
30 g
Shock, nonoperating
50 g
Propagation delay (worst-case)
94 ns

Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp