Allen-Bradley 1794-OA8 FLEX I/O Digital Output Module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1794-OA8 FLEX I/O Digital Output Module
  • Inputs: 0
  • Outputs: 8
  • Electrical category: 120V AC

Specification

Allen-Bradley 1794-OA8 FLEX I/O Digital Output Module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1794-OA8
Inputs0
Outputs8
Electrical category120V AC
I/O arrangementNonisolated outputs
Listed terminal bases1794-TBNF, 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TBN, 1794-TBKD, 1794-TB3K, 1794-TB3SK, 1794-TBNK

1794-OA8 Procurement Questions

Which terminal base units can be used with the 1794-OA8?

The listed terminal base units are 1794-TBN, 1794-TBNF, 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TBKD, 1794-TBNK, 1794-TB3K and 1794-TB3SK.

What on-state output current can the 1794-OA8 carry at elevated ambient temperature?

The maximum is 500 mA per output @ 55 °C; 750 mA per output @ 35 °C; 1.0 A on 4 nonadjacent outputs and 500 mA on the remaining 4 outputs @ 30 °C.

How much off-state leakage current should be expected from the 1794-OA8 outputs?

The maximum off-state output leakage current is 2.25 mA.

What surge current can the 1794-OA8 outputs handle?

The maximum output surge current is 7 A for 45 ms, repeatable every 8 s.

What fusing is recommended for the 1794-OA8 outputs?

Use a 1.6 A, 250V slow-blow fuse (Littelfuse part number 23901.6; San-o SD6-1.6 A, AB part number 94171304); the 1794-TBNF comes with SD6-1.6 A fuses installed.

What is the operating temperature range of the 1794-OA8?

The operating temperature range is -20…+55 °C (-4…+131 °F).

Voltage, on-state output, nom
120V AC
Terminal base unit
1794-TBN, 1794-TBNF, 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TBKD, 1794-TBNK, 1794-TB3K, 1794-TB3SK
Current, on-state output, min
5 mA per output
Current, on-state output, max
500 mA per output @ 55 °C; 750 mA per output @ 35 °C; 1.0 A on 4 nonadjacent outputs and 500 mA on the remaining 4 outputs @ 30 °C
Current, on-state output, per module
4.0 A (8 outputs @ 500 mA)
Leakage current, off-state output, max
2.25 mA
Voltage drop, on-state output, max
1.0V @ 0.5 A
Output surge current, max
7 A for 45 ms, repeatable every 8 s
Voltage, on-state output, min
85V AC
Voltage, on-state output, max
132V AC
Power dissipation, max
4.1 W @ 0.5 A; 6.3 W @ 0.75 A; 6.3 W @ 1.0 A
Thermal dissipation, max
14.0 BTU/hr @ 0.5 A; 21.1 BTU/hr @ 0.75 A; 21.4 BTU/hr @ 1.0 A
Dimensions (HxWxD), approx
46 x 94 x 53 mm (1.8 x 3.7 x 2.1 in); 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in) installed
Isolation voltage
120V (continuous), I/O to system; no isolation between individual channels; tested to 2150V DC for 1 s and 1250V AC for 60 s
Temperature, operating
-20…+55 °C (-4…+131 °F)
Recommended output fusing
1.6 A, 250V slow-blow fuse (Littelfuse part number 23901.6; San-o SD6-1.6 A, AB part number 94171304); the 1794-TBNF comes with SD6-1.6 A fuses installed

Technical specifications are based on the linked manufacturer reference.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp