Allen-Bradley 1794-OW8 FLEX I/O Relay Output Module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1794-OW8 FLEX I/O Relay Output Module
  • Relay outputs: 8 isolated Form A (normally open) contacts
  • Contact rating envelope: Up to 2 A; voltage up to 230V AC or 125V DC. These maxima are not a simultaneous current/voltage rating; apply the switching and load ratings.
  • Listed terminal bases: 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TBN, 1794-TBNF, 1794-TB3SK, 1794-TBNK

Specification

Allen-Bradley 1794-OW8 FLEX I/O Relay Output Module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1794-OW8
Relay outputs8 isolated Form A (normally open) contacts
Contact rating envelopeUp to 2 A; voltage up to 230V AC or 125V DC. These maxima are not a simultaneous current/voltage rating; apply the switching and load ratings.
Listed terminal bases1794-TB2, 1794-TB3, 1794-TB3S, 1794-TBN, 1794-TBNF, 1794-TB3SK, 1794-TBNK

1794-OW8 Procurement Questions

What contact configuration does the 1794-OW8 provide?

It provides 8 isolated Form A (normally open) contacts, capable of switching up to 2 A at up to 230V AC and 125V DC.

Which terminal base units can be used with this module?

The listed terminal base units are 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TBN, 1794-TBNF, 1794-TB3K, 1794-TB3SK and 1794-TBNKF.

What external DC supply does the module require?

The external DC supply voltage range is 19.2…31.2V DC (includes 5% AC ripple), and the nominal external DC supply current is 125 mA.

Is external fusing needed for the outputs?

Yes. The use of external fuses or a fused terminal base is required for individual outputs; the fusing specified is a 3.0 A, 250V AC slow-blow fuse (Littelfuse part number 239003).

What are the resistive and inductive relay output current ratings?

Resistive: 2.0 A @ 5…30V DC; 0.22 A @ 125V DC; 2.0 A @ 125V AC; 2.0 A @ 250V AC. Inductive: 0.98 A steady state @ 5…30V DC, L/R = 7 ms; 0.5 A steady state @ 48V DC, L/R = 7 ms; 0.22 A steady state @ 125V DC, L/R = 7 ms; 2.0 A steady state, 15 A make @ 120V AC, PF = cos θ = 0.35; 2.0 A steady state, 7.5 A make @ 240V AC, PF = cos θ = 0.35.

What is the maximum output delay time in each direction?

The maximum output delay time is 10 ms OFF to ON and 10 ms ON to OFF.

Relay contacts
8 isolated Form A (normally open) contacts, capable of switching up to 2 A at up to 230V AC and 125V DC
Terminal base current limit
Total current draw through the terminal base unit is limited to 10 A; separate power connections to the terminal base unit may be necessary
Number of outputs
8
Terminal base unit
1794-TB2, 1794-TB3, 1794-TB3S, 1794-TBN, 1794-TBNF, 1794-TB3K, 1794-TB3SK, 1794-TBNKF
External DC supply voltage range
19.2…31.2V DC (includes 5% AC ripple)
External DC supply current, nom
125 mA
Leakage current, off-state output, max
1 mA @ 240V AC (through a snubber)
Output delay time, OFF to ON, max
10 ms
Output delay time, ON to OFF, max
10 ms
Relay output current rating, resistive
2.0 A @ 5…30V DC; 0.22 A @ 125V DC; 2.0 A @ 125V AC; 2.0 A @ 250V AC
Relay output current rating, inductive
0.98 A steady state @ 5…30V DC, L/R = 7 ms; 0.5 A steady state @ 48V DC, L/R = 7 ms; 0.22 A steady state @ 125V DC, L/R = 7 ms; 2.0 A steady state, 15 A make @ 120V AC, PF = cos θ = 0.35; 2.0 A steady state, 7.5 A make @ 240V AC, PF = cos θ = 0.35
Contact resistance, initial
30 mΩ
Switching frequency
0.3 Hz (1 operation every 3 s)
Bounce time, mean
1.2 ms
Contact load, min
100 µA @ 100 mV DC
Mechanical life
100,000 operations at rated loads
Fusing
3.0 A, 250V AC slow-blow fuse (Littelfuse part number 239003)
External fusing
The use of external fuses or a fused terminal base is required for individual outputs
Power dissipation, max
5.5 W @ 31.2V DC
Thermal dissipation, max
18.8 BTU/hr @ 31.2V DC
Dimensions (HxWxD), approx
46 x 94 x 53 mm (1.8 x 3.7 x 2.1 in); 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in) installed
Isolation voltage
250V (continuous), Basic Insulation Type, relay to relay, relay to backplane, and relay to power; 50V (continuous), Basic Insulation Type, power to backplane; type tested at 1500V AC for 60 s, relay to relay, all combinations; type tested at 3250V DC for 60 s, relay to backplane and relay to power; type tested at 720V DC for 60 s, power to backplane
Temperature, operating
-20…+55 °C (-4…+131 °F)

Technical specifications are based on the linked manufacturer reference.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp