1794-IT8 Procurement Questions
What input range does the 1794-IT8 accept from a mV source?
The module accepts mV source inputs in the range of ±76.5 mV, and it also accepts inputs from a variety of thermocouples, grounded or ungrounded.
Which thermocouple types can the 1794-IT8 measure, and over what ranges?
Type B: 300…1800 °C (572…3272 °F); Type C: 0…2315 °C (32…4199 °F); Type E: -270…+1000 °C (-454…+1832 °F); Type J: -210…+1200 °C (-346…+2192 °F); Type K: -270…+1372 °C (-454…+2502 °F); Type N: -270…+1300 °C (-454…+2372 °F); Type R: -50…+1768 °C (-58…+3214 °F); Type S: -50…+1768 °C (-58…+3214 °F); Type T: -270…+400 °C (-454…+752 °F); Type TXK/XK (L): -200…+800 °C (-328…+1472 °F).
Is cold junction compensation supplied with the module?
Yes. A-B Cold Junction Compensation Kit 1794-CJC is specified, and cold junction compensator kit 1794-CJC2 (two compensators) is included with the module. The cold junction compensation range is 0…70 °C.
How does the module report an open input?
Open input detection is available at system throughput rate, and the open circuit detection type is an out of range reading (upscale).
What accuracy and drift figures apply to the 1794-IT8?
With filter (max) accuracy is 0.025% Full Scale @ 24 °C (±0.5 °C); without filter (max) it is 0.05% Full Scale @ 24 °C (±0.5 °C). Input offset drift with temperature is +6 μV/°C max, gain drift with temperature max is 10 ppm/°C, and overall drift with temperature max is 50 ppm/°C of span.
What are the system throughput and operating temperature of the 1794-IT8?
System throughput is 325 ms (1 channel scanned), programmable to 28 ms, and 2.6 s (8 channels scanned), programmable to 224 ms. Operating temperature is -20…+55 °C (-4…+131 °F).
- mV input range
- Temperature/mV measuring module; mV source input range ±76.5 mV; supports grounded or ungrounded thermocouples
- Cold junction compensators
- Cold junction compensator kit 1794-CJC2 (two compensators) is included with the module
- Input resolution
- 16 bits (2.384 μV typical)
- Supported thermocouple types
- Type B: 300…1800 °C (572…3272 °F); Type C: 0…2315 °C (32…4199 °F); Type E: -270…+1000 °C (-454…+1832 °F); Type J: -210…+1200 °C (-346…+2192 °F); Type K: -270…+1372 °C (-454…+2502 °F); Type N: -270…+1300 °C (-454…+2372 °F); Type R: -50…+1768 °C (-58…+3214 °F); Type S: -50…+1768 °C (-58…+3214 °F); Type T: -270…+400 °C (-454…+752 °F); Type TXK/XK (L): -200…+800 °C (-328…+1472 °F)
- Data format
- 16 bits, 2's complement; offset binary (unipolar)
- Settling time
- 100% of final value available at system throughput rate
- Normal mode rejection ratio
- 60 dB @ 60 Hz
- Common mode rejection ratio
- -115 dB @ 60 Hz; -100 dB @ 50 Hz
- Common mode input range
- ±10V
- Accuracy
- With filter (max): 0.025% Full Scale @ 24 °C (±0.5 °C); without filter (max): 0.05% Full Scale @ 24 °C (±0.5 °C)
- System throughput
- 325 ms (1 channel scanned), programmable to 28 ms; 2.6 s (8 channels scanned), programmable to 224 ms
- Open input detection
- Available at system throughput rate
- Open circuit detection type
- Out of range reading (upscale)
- Overvoltage capability
- 35V DC, 25V AC continuous @ 25 °C; 250V peak transient
- Channel bandwidth
- 0…2.62 Hz (-3 dB)
- RFI immunity
- Error of <1% of range @ 10V/m, 27…1000 MHz
- Input offset drift with temperature
- +6 μV/°C max
- Gain drift with temperature, max
- 10 ppm/°C
- Overall drift with temperature, max
- 50 ppm/°C of span
- Cold junction compensation range
- 0…70 °C
- Cold junction compensation
- A-B Cold Junction Compensation Kit, 1794-CJC
- Dimensions (HxWxD), approx
- 46 x 94 x 53 mm (1.8 x 3.7 x 2.1 in); 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in) installed
- Temperature, operating
- -20…+55 °C (-4…+131 °F)