Allen-Bradley 1794-OE8H FLEX I/O HART Analog Output Module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1794-OE8H FLEX I/O HART Analog Output Module
  • Output channels: 8
  • Output signals: 0–20 mA HART field devices
  • HART connections: One HART field device per channel; use with 2-wire devices

Specification

Allen-Bradley 1794-OE8H FLEX I/O HART Analog Output Module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1794-OE8H
Output channels8
Output signals0–20 mA HART field devices
HART connectionsOne HART field device per channel; use with 2-wire devices
Channel isolationNo isolation between individual channels

1794-OE8H Procurement Questions

What field devices can the 1794-OE8H drive?

It works with HART enabled field devices that use current in the 0…20 mA range, with 2-wire devices, and one HART field device per channel.

On which networks can this module be used?

The module can be used on ControlNet, EtherNet/IP, or PROFIBUS DP networks.

What output resolution and conversion rate does the module provide?

Output resolution is 13 bit, the data format is configurable, and the output conversion rate is 10 ms for all channels.

How fast does the output respond to a step change?

Step response to 99% of FS is 13 ms, and 115 ms during HART communication.

What resistive load can the output current drive?

Output current supports a resistive load of 0…680 Ω @ 22 mA and 0…770 Ω @ 20 mA.

What wire size does the module accept?

Wire size is 0.34…2.5 mm2 (22...12 AWG) solid or stranded shielded copper wire rated at 75 °C (167 °F) or greater, with 1.2 mm (3/64 in.) insulation max.

HART function
HART enabled analog output module for HART enabled field devices using current in the 0…20 mA range; use with 2-wire devices; wire-off detection on a per-channel basis; usable on ControlNet, EtherNet/IP, or PROFIBUS DP networks; one HART field device per channel
Output resolution
13 bit
Data format
Configurable
Output conversion rate
10 ms for all channels
Step response to 99% of FS, output
13 ms to 99% of FS; 115 ms during HART communication
Current load on voltage output, max
0…22 mA @ >15V
Output current, resistive load
0…680 Ω @ 22 mA; 0…770 Ω @ 20 mA
Accuracy
0.1% Full Scale @ 20 °C (68 °F)
Accuracy drift with temperature
0.010% Full Scale @ 20 °C (68 °F)
Isolation voltage
50V (continuous), Basic Insulation Type; no isolation between individual channels
Power dissipation, max
6.1 W
Thermal dissipation, max
20.8 BTU/hr
Wire size
0.34…2.5 mm2 (22...12 AWG) solid or stranded shielded copper wire rated at 75 °C (167 °F) or greater; 1.2 mm (3/64 in.) insulation max
Wire category
2 – on signal ports; 2 – on power ports
Dimensions (HxWxD), approx
46 x 94 x 75 mm (1.8 x 3.7 x 2.95 in); 94 x 94 x 91 mm (3.7 x 3.7 x 3.6 in) installed
Temperature, operating
-20…+55 °C (-4…+131 °F)

Technical specifications are based on the linked manufacturer reference.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp