1794-OE12 Procurement Questions
What output ranges does the 1794-OE12 support?
It provides current in the range of 0…20 mA or voltage in the range of ±10V, depending on user configuration, and an out-of-range status bit exists for each channel.
What is the maximum current load on the voltage output?
The current load on voltage output, max, is 3 mA.
What resistive load can the current output drive?
Output current with resistive load is 0…750 Ω over full power supply range.
Is calibration required for this module?
No; calibration is listed as none required.
What isolation does the 1794-OE12 provide?
Isolation voltage is 50V (continuous), Basic Insulation Type, type tested at 850V DC for 60 s between field side and system; there is no isolation between individual channels.
What wire size and wire category apply?
Wire size is 0.34…2.5 mm2 (22...12 AWG) solid or stranded shielded copper wire rated at 75 °C (167 °F) or greater, with 1.2 mm (3/64 in.) insulation max; wire category is 2 on signal ports and 2 on power ports.
- Output ranges
- Current in the range of 0…20 mA or voltage in the range of ±10V, depending on user configuration; out-of-range status bit exists for each channel
- Output resolution
- 320 μV/cnt; 0.641 μA/cnt
- Data format
- Configurable
- Output conversion type
- Digital to analog converter
- Output conversion rate
- Outputs: DAC
- Step response to 63% of FS, output
- ~70% 1st convert; 96% 2nd convert; 100% 3rd convert
- Current load on voltage output, max
- 3 mA
- Output current, resistive load
- 0…750 Ω over full power supply range
- Accuracy
- Current output: 0.1% Full Scale at 25 °C; voltage output: 0.1% Full Scale at 25 °C
- Accuracy drift with temperature
- Current output: 0.004% Full Scale/°C; voltage output: 0.004% Full Scale/°C
- Calibration
- None required
- Isolation voltage
- 50V (continuous), Basic Insulation Type; type tested at 850V DC for 60 s, between field side and system; no isolation between individual channels
- Power dissipation, max
- 4.0 W @ 31.2V DC; 4.3 W @ 24V DC; 4.0 W @ 10.0V DC
- Thermal dissipation, max
- 14.7 BTU/hr @ 24V DC
- Wire size
- 0.34…2.5 mm2 (22...12 AWG) solid or stranded shielded copper wire rated at 75 °C (167 °F) or greater; 1.2 mm (3/64 in.) insulation max
- Wire category
- 2 – on signal ports; 2 – on power ports
- Dimensions (HxWxD), approx
- 46 x 94 x 53 mm (1.8 x 3.7 x 3.1 in); 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in) installed
- Temperature, operating
- -20…+60 °C (-4…+140 °F)