Allen-Bradley 1794-IP4 FLEX I/O Pulse Counter Module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1794-IP4 FLEX I/O Pulse Counter Module
  • Input channels: 4
  • Input threshold: 6V minimum for input On; 3V maximum for input Off
  • Operating temperature: 0–55 °C (32–131 °F)

Specification

Allen-Bradley 1794-IP4 FLEX I/O Pulse Counter Module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1794-IP4
Input channels4
Input threshold6V minimum for input On; 3V maximum for input Off
Operating temperature0–55 °C (32–131 °F)

1794-IP4 Procurement Questions

What input voltage thresholds does the 1794-IP4 apply?

The module has a 6V minimum threshold for an input ON condition and a 3V maximum threshold for an input OFF condition; all input devices should be able to provide an input signal of 6V amplitude.

What is the maximum counting frequency of the 1794-IP4?

The maximum counting frequency is 100 kHz, and each signal condition must be stable for at least 2 ms to be recognized.

What input current does the module draw at the specified signal voltages?

The input signal range is 3 mA @ 6V DC, 9 mA @ 12V DC and 15 mA @ 24V DC.

How does the overflow period depend on the selected internal clock?

The maximum period is 65 ms when the 1 MHz internal clock is selected and 6.5 ms when the 10 MHz internal clock is selected.

What are the dimensions of the 1794-IP4?

Approximate dimensions are 46 x 94 x 53 mm (1.8 x 3.7 x 3.1 in), or 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in) installed.

What operating temperature range is specified for the 1794-IP4?

The operating temperature range is 0…55 °C (32…131 °F).

Input thresholds
Input ON condition threshold 6V minimum; input OFF condition threshold 3V maximum; all input devices should be able to provide an input signal of 6V amplitude
Counting frequency, max
100 kHz
Input frequency, max
100
Input signal range
3 mA @ 6V DC; 9 mA @ 12V DC; 15 mA @ 24V DC
Overflow
Maximum period – 65 ms when 1 MHz internal clock selected; maximum period – 6.5 ms when 10 MHz internal clock selected
Signal stability (table footnote (1))
Each signal condition must be stable for at least 2 ms to be recognized
Dimensions (WxHxD), approx
46 x 94 x 53 mm (1.8 x 3.7 x 3.1 in); 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in) installed
Temperature, operating
0…55 °C (32…131 °F)

Technical specifications are based on the linked manufacturer reference.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp